Catalogue

In our production program there are:

  • High pressure sodium lamps - standard type
    Various applications possible
    Reliable operation

    The very high light output of standard high pressure sodium lamps type WLS makes them particulary suitable for exterior lighting of the streets and roads, building sites, parks and industrial areas. Standard WLS lamps may be also used for industrial workshops lighting if work does not last too long and if there is no need to distinguish colors precisely.

  • High pressure sodium lamps - retrofit type
    It is possible to improve lighting on the cheap
    There is a category of high pressure sodium lamps, sometimes called retrofit type, designed specially for replacement of mercury lamps. This can be done by simply plugging these new lamps into existing, conventional mercury lamps sockets. No changes to the lighting installation are required. High pressure sodium lamps deliver more light while consuming less electricity than the mercury lamps they replace.

  • High pressure sodium lamps - high output type
    The light output goes higher and higher ...

  • High pressure mercury vapour lamps
    Mercury vapour lamps type LRF are modern light sources where a visible radiation is caused by electrical discharge in mercury vapour and inert gas. Elliptical bulb of the lamp is covered inside by the special phosphor layer which converts ultraviolet radiation to visible light with satisfying level of colours intensity.

  • Blended light lamps MixF

Blended light lamps type MixF are the universal light sources combining features of mercury lamps and incandescent light bulbs. They consist of a quartz mercury arc tube connected in series with tungsten filament, which gives full luminous flux in the moment when the lamp is switched on, colour temperature is better and it works as a ballast.

We can offer also from polish lighting industry :

  • CORTES-MICHALAK (Warsaw)
    Ignitors for HID lamps

  • ELGO (Gostynin)
    Surface mounted luminaires
    Interior lighting fittings for public services suitable for most type of ceiling
    Interior lighting fittings with cover for public services
    Open interior lighting fittings for public services and industry
    Interior lighting fittings
    Outdoors fixtures
    Industrial lighting fittings
    Luminaires for green houses
    Luminaires : pictograph, advertisement
    Ballasts for fluorescent lamps
    Ballasts for high pressure sodium and mercury lamps
    And others
  page up

 

 

 

 

 

Catalogue

HIGH PRESSURE SODIUM LAMPS - standard type
Various application possible - Reliable operation

  • Burner made from translucent polycrystalline alumina tube special doped to achieve reduction of darkening on the ends.
  • High quality, sealing material resistant to the aggressive sodium vapour.
  • Special emmission material improving the ignition and life time.
  • High purity sodium amalgam with constant composition and weight.
  • Special support construction resistant to the mechanical shocks and vibrations.
  • Any burning positions.
  • Good quality, non-corrosive, nickel plated cap with ceramic isolator.
  • Special program of the inspection decrease early failure.
  • Lamps can be used in all types of the luminaires which comply IEC standard.
 

High pressure sodium lamps - standard type

Type Execution Luminous
flux

[lm]
Luminous
efficacy

[lm/W]
Wattage

[W]
Current

[A]
Lamp
voltage

[V]
Base
type
Bulb
shape/
finish
WLS 70 EC 6 000 86 70 0,98 90 E 27 elipsoidal, clear
WLS 70 ED 5 600 80 70 0,98 90 E 27 elipsoidal, coated
WLS 100 TC 8 800 88 100 1,20 100 E 40 tubular, clear
WLS 150 TC 14 500 97 150 1,80 100 E 40 tubular, clear
WLS 150 ED 14 000 93 150 1,80 100 E 40 elipsoidal, coated
WLS 250 TC 27 000 108 250 3,00 100 E 40 tubular, clear
WLS 250 ED 26 000 104 250 3,00 100 E 40 elipsoidal, coated
WLS 400 TC 48 000 120 400 4,60 100 E 40 tubular, clear
WLS 400 ED 46 000 115 400 4,60 100 E 40 elipsoidal, coated

 

 

HIGH PRESSURE SODIUM LAMPS - retrofit type
It is possible to improve lighting on the cheap

Please remember that:

  • sodium retrofit lamp WLS 110W r eplaced mercury lamp 125W
  • sodium retrofit lamp WLS 210W replaced mercury lamp 250W
  • sodium retrofit lamp WLS 330W replaced mercury lamp 400W


High pressure sodim lamps - retrofit type

Type Execution Luminous
flux

[lm]
Luminous
efficacy

[lm/W]
Wattage

[W]
Current

[A]
Lamp
voltage

[V]
Base
type
Bulb
shape/
finish
WLS 110 ED 8 000 73 110 1,20 110 E 27 elipsoidal, coated
WLS 210 ED 18 000 85 210 2,30 115 E 40 elipsoidal, coated
WLS 330 ED 32 000 97 330 3,40 110 E 40 elipsoidal, coated

 

HIGH PRESSURE SODIUM LAMPS - high output type
T
he light output goes higher and higher ...

The extraordinery energy efficiency is made possible by a higher xenon fill pressure in the arc tube which increase lumen output.

High pressure sodium lamps - high output type

Type Execution Luminous
flux

[lm]
Luminous
efficacy

[lm/W]
Wattage

[W]
Current

[A]
Lamp
voltage

[V]
Base
type
Bulb
shape/
finish
WLS 70 EC EXTRA 6 500 93 70 0,98 90 E 27 elipsoidal, clear
WLS 100 TC EXTRA 10 000 100 100 1,20 100 E 40 tubular, clear
WLS 150 TC EXTRA 17 000 113 150 1,80 100 E 40 elipsoidal, coated
WLS 250 TC EXTRA 32 000 128 250 3,00 100 E 40 elipsoidal, coated
WLS 400 TC EXTRA 55 000 137 400 4,60 100 E 40 tubular, clear

 
OTHER DATA

DIMENSIONS

Lamp
type
Lamp lenght
L max.
(mm)
Lamp diameter
D max.
(mm)
Light center lenght
LCL
(mm)
WLS 70 EC 165 71 105
WLS 70 ED 165 71 -
WLS 70 EC EXTRA 165 71 105
WLS 100 TC 211 47 132
WLS 100 TC EXTRA 211 47 132
WLS 150 TC 211 47 132
WLS 150 ED 211 91 -
WLS 150 TC EXTRA 211 47 132
WLS 250 TC 260 47 158
WLS 250 ED 260 91 -
WLS 250 TC EXTRA 260 47 158
WLS 400 TC 292 47 175
WLS 400 ED 292 121 -
WLS 400 TC EXTRA 292 47 175
WLS 110 ED 175 76 -
WLS 210 ED 227 91 -
WLS 330 ED 292 121 -

 

   Minimum lamp voltage 198 V
   Colour temperature 2050 K
   Colour rendering index CRI 23
   Burning position any
   Warm up time (to 100% output) COLD about 7 min.
   Warm up time (to 80% output) HOT about 4 min.
   Restart time for hot lamps about 1 min.
   Max. permissible base temperature 210oC
   Max. permissible bulb temperature 400oC

 

 

High pressure mercury vapour lamps

Mercury vapour lamps type LRF are modern light sources where a visible radiation is caused by electrical discharge in mercury vapour and inert gas. Elliptical bulb of the lamp is covered inside by the special phosphor layer which converts ultraviolet radiation to visible light with satisfying level of colours intensity.

Features:

  • high lighting stability to 58 lm/W
  • short run up time
  • solid construction ensuring resistance to shock and vibrations
  • universal burning position
  • in the fitting, apart from ballast, lamp does not require any additional devices
 

Application:

  • street lighting
  • indoor lighting – industrial or sport halls
  • utdoor lighting – parks, recreational grounds

Technical parameters

TECHNICAL PARAMETERS
TYPE
LRF
80W
LRF
125W
LRF
250W
LRF
400W
LRF
700W
LRF
1000W
Rated wattage [W]
80
125
250
400
700
1000
Lamp voltage [V]
115
125
130
135
140
145
Lamp current [A]
0,8
1,15
2,13
3,25
5,4
7,5
Warm-up current [A}
1,25
1,75
4,5
5,5
10,0
15,0
Luminous flux [Im]
3700
6300
13000
22000
38000
58000
App colour temperature [K]
4000
4000
3900
3900
3600
3600
Cap
E27
E27
E40
E40
E40
E40
Burning position
any
Dimensions [mm]  
71
76
91
122
152
167
 
166
178
228
292
357
411

 

 

Blended light lamps MixF

Blended light lamps type MixF are the universal light sources combining features of mercury lamps and incandescent light bulbs. They consist of a quartz mercury arc tube connected in series with tungsten filament, which gives full luminous flux in the moment when the lamp is switched on, colour temperature is better and it works as a ballast.

Features:

  • direct interchangeable product of incandescent lamps, lamps work without any additional ballasts and ignition devices
  • immediate ignition
  • pleasant colour of light
  • long life
 

Application:

  • outdoor lighting – streets, pedestrian zones
  • indoor lighting - sport and industrial objects
  • lighting at parks and gardens
  • lighting at greenhouses

Technical parameters

TECHNICAL PARAMETERS
TYPE
MixF
160W
MixF
250W
MixF
500W
Operating voltage [V]
220-230/230-240
Rated wattage [W]
160
250
500
Lamp current [A]
0,75
1,25
2,5
Warm-up current [A]
1,3
2,1
3,7
Luminous flux [Im]
3100
5700
13000
App colour temperature [K]
3600
3800
4100
Cap
E27
E40
E40
Burning position
cap upwards
+/- 30o
any
Dimensions [mm]
D max
76
91
122
L max
180
227
288

 

  polish version page up